Dark rod ammonia shut-off valve

Products > Globe valve > Dark rod ammonia shut-off valve

Dark rod ammonia shut-off valve

Model: J41B
Nominal diameter: DN15 ~ DN300
Nominal pressure: PN16 ~ PN25
Medium: liquid, gas, ammonia, nitrogen, hydrogen,
Temperature: -10 ℃ -150 ℃
Body Material: Cast iron, cast steel
Operation: manual , gear drive, electric, pneumatic and other
design and manufacturing: GB12235
structural length: GB12221
flange dimensions: GB9113 JB79
pressure - temperature: GB9131
test - test: GB / T13927 JB / T9092
shared:

1. Structural features and uses
1. The medium-pass flange is square structure, and the valve stem is connected by a rod. 
2. The sealing surface of the valve body adopts a spherical convex shape, and is sealed with the valve foot by a line. 
3. The sealing surface is made of babbitt alloy, which has good sealing performance and long service life.

       Ammonia shut-off valves often use oxygen, nitrogen, hydrogen, argon and other gases. These gases are typically stored in dedicated high pressure gases. When in use, the gas pressure is reduced to the required range by the ammonia shut-off valve, and then finely adjusted by other control valves to make the gas input into the system. The most commonly used pressure reducing valve is a shut-off valve for ammonia, referred to as a valve for ammonia. 

Second, the performance specification

Nominal pressure PN (MPA)

Test pressure PS (MPa)

Applicable medium

Applicable temperature (°C)

2.5

3.8

Ammonia gas, 
liquid ammonia and the like 
NH3

Babbitt alloy 
-40 ° C 
+150 ° C

PTFE 
-40 ° C 
+200 ° C

4.0

6.4

Third, the main size and weight:

Nominal diameter 
DN (mm)

Size (mm)

L

D

D1

D2

D4

b

f

F1

Z-φd

turn off

open

D3

10

130

90

60

40

35

16

2

4

4-φ14

165

185

110

15

130

95

65

45

40

16

2

4

4-φ14

165

185

110

20

150

105

75

55

51

18

2

4

4-φ14

170

200

120

25

160

115

85

65

58

18

2

4

4-φ14

197

210

120

32

180

135

100

78

66

20

2

4

4-φ18

199

213

140

40

200

145

110

85

76

20

3

4

4-φ18

248

264

160

50

230

160

125

100

88

twenty two

3

4

4-φ18

265

295

180

65

290

180

145

120

110

twenty four

3

4

8-φ18

310

349

220

80

310

195

160

135

121

26

3

4

8-φ18

340

357

240

100

350

230

190

160

150

30

3

4.5

8-φ23

380

413

280

125

400

270

220

188

176

32

3

4.5

8-φ25

430

451

320

150

480

300

250

218

204

32

3

4.5

8-φ25

505

492

360

200

600

360

310

278

260

34

3

4.5

12-φ25

550

806

400

250

650

425

370

335

31

36

3

4.5

12-φ30

730

880

450

300

750

485

430

390

364

40

3

4.5

16-φ30

-

995

550

 

Fourth, the appearance and working principle
       The high pressure chamber of the ammonia valve is connected with the cylinder, the low pressure chamber is the gas outlet, and leads to the use system. The indication of the high pressure gauge is the pressure of the stored gas in the cylinder. The outlet pressure of the low pressure gauge can be controlled by an adjustment screw. 
       When using, first open the cylinder main switch, then turn the low pressure gauge pressure adjusting screw clockwise to compress the main spring and drive the film, spring block and ejector to open the valve. The imported high-pressure gas is depressurized by the high-pressure chamber and then enters the low-pressure chamber and leads to the working system through the outlet. Turn the adjusting screw to change the height at which the valve opens, thereby adjusting the throughput of the high pressure gas and achieving the desired pressure value. 
       The ammonia shut-off valve is equipped with a safety valve. It is a device that protects the ammonia gas pressure reducing valve and makes it safe to use, and is also a signal device for the failure of the ammonia gas pressure reducing valve. If the outlet pressure rises by itself and exceeds a certain permissible value due to damage to the valve mat, valve or other reasons, the safety valve automatically opens the exhaust.

V. Method of use
(1) There are many specifications for ammonia gas pressure reducing valves depending on the requirements of use. The highest import pressure is mostly, the minimum import pressure is not less than 2.5 times the export pressure. There are many export pressure specifications, generally, the highest outlet pressure is.   
(2) When installing the ammonia gas pressure reducing valve, make sure that the connection specifications are consistent with the joints of the system. The ammonia shut-off valve is connected by a hemispherical surface, and the nut is fully fitted by tightening the nut. Therefore, the two hemispheres should be kept clean during use to ensure a good airtight effect. High pressure gas can be used to blow off dust before installation. If necessary, a material such as polytetrafluoroethylene may be used as the gasket. 
(3) The shut-off valve for ammonia should be strictly prohibited from contact with grease to avoid a fire accident. 
(4) When the work is stopped, the residual gas in the pressure reducing valve should be drained, and then the adjusting screw should be loosened to prevent the elastic component from being deformed for a long time. 
(5) The shut-off valve for ammonia should avoid impact vibration and should not be in contact with corrosive substances.